CTD Probe


Different parameters measurement and data analysis with Smartyplanet

 

The CTD SP36XWCTD multiparameter probe is the ideal solution for measuring water level, temperature and conductivity parameters.

It is designed for the hydrological control of different places such as rivers or water treatment plants.

The data collected by the sensors are accurate and reliable. Thanks to the full compatibility of the probe with the Smartyplanet web platform, the data is recorded and analyzed instantly.

 

Datasheet

Description

The CTD SP36XWCTD multiparameter probe is the ideal solution for measuring water level, temperature and conductivity parameters.
It is designed for the hydrological control of different places such as rivers or water treatment plants.
The data collected by the sensors are accurate and reliable. Thanks to the full compatibility of the probe with the Smartyplanet web platform, the data is recorded and analyzed instantly.
The robust construction of the multiparameter probe makes its installation can be carried out in any type of water.
The maintenance required by the probe is minimal.
  • Environmental monitoring
  • Surveillance of groundwater
  • Water Treatment Plants
  • Hydrological control
  • 5 ppm pressure sensor
  • Mathematical Compensation of Nonlinearities and Temperature Dependencies
  • Robust stainless steel case
  • Lightning protection installed
  • SDI-12 interface
  • Wide range of level measurement
  • Long-Term Stability

Specifications

SENSOR PARAMETERSSPECIFICATIONS
PRESSURE

Relative pressure
Absolute pressure
Water column meters
0,3 1 3 10 30
0,8..2,3 0,8...4 0,8...11 0,8...31
3 10 30 100 300
Overload resistancemax. 300%
Technology
Oil-filled, insulated, piezoresistive
Pressure transducer in a metal housing
Resolutiontyp. 5 ppm (corresponding to 0,0005 %FS)
Accuracy± 0,02 %FS max.
(0,3 bar Range: ± 0,04 %FS)
Temperature range0 to 50ºC
Total error± 0,1 %FS max.
(0,3 bar Range: ± 0,2 %FS)
Operating temperature-20 to +80ºC
Measuring interval120, 240 (default), 480 Hz
Stabilityrange > 1 bar: ± 0,1 %FS max.
range ≤ 1 bar: ± 1 mbar max.
Dependance grade on locations± 1,5 mbar max.
TEMPERATURE
Measurement range-10 to +80ºC
TechnologySillicon
Resolution< 0,01 °C
AccuracySillicon sensor typ. ± 0,3 °C
Pt1000 sensor: ± 0,1 °C max.
Measurement interval12 Hz TOB
6 Hz Pt1000 without conductivity
1 Hz Pt1000 with conductivity
CONDUCTIVITY
Measurement range0 μS/cm…200 mS/cm
Selectable ranges with software0,2 / 2* / 20 / 200* mS/cm
Technology6 platinum electrodes, 4-wire technology
Temperature range-10 to +60ºC
Resolution< 0,05% of selectable range
Accuracy< 2,5% of selectable range
Measurement interval1 Hz
PARAMETERSSPECIFICATIONS
ELECTRICAL DATARS485SDI-12
Power supply
3,2 to 32 VDC6 to 32 VDC
Power consumption<6mA (without conductivity)
<14mA (with conductivity)
<0,1mA
<5,5mA (without conductivity)
<13 mA(with conductivity)
Starting time<300ms (P1, TOB1)
3s, 6s max. (P1, T, Con)
<1s
<3s
GND> 10 MΩ @ 300 V
Resistance> 10 mio. pressure cycles
0…100 %FS @ 25 °C
Storage temperature-20 to +80ºC
DIGITAL INTERFACERS485SDI-12
Communication protocolMODBUS RTU
KELLER bus
SDI-12 V1.3
Baud Rates9600*, 115’200 bit/s1200 bit/s
IdentificationGroup Class: 5.21
Pressure unitsbarbar, mbar, mH2O,
psi, ftWC, inWC
Temperature unitsºCºC, ºF, K
Conductivity unitsmS/cmmS/cm
MECHANICAL DATA
Dimensionsø 22 mm
Weight170 g without wire
Housing material316 stainless steel
Wire materailRelative pressure: PE
Absolut pressure: PE
STANDARDS AND PROTECTION
EMC standardEN 61000-6-2: 2005
EN 61000-6-3: 2007
EN 61326-2-3: 2006
Reverse polarity and overload protection± 32 VDC supply and RS485
± 24 VDC SDI-12
Protection classIP68